Model | Sygnalizacja | Napis informacyjny | Napięcie zasilania | Wymiary |
---|---|---|---|---|
TP-4.s/H0 | SYG + OPT | (zgodnie z zamówieniem) | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H1 | SYG + OPT |
NIE WCHODZIĆ NADMIAR SPALIN | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H3 | SYG + OPT | NIE WJEŻDŻAĆ NADMIAR SPALIN | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H4 | SYG + OPT | WYCIEK AUTOGAZU ZACHOWAĆ OSTROŻNOŚĆ | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H5 | SYG + OPT | UWAGA! NADMIAR SPALIN | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H7 | SYG + OPT | WYCIEK WODORU ZACHOWAĆ OSTROŻNOŚĆ | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H8 | SYG + OPT |
ALARM CO2 NIE WCHODZIĆ | 230V~ | 555 x 155 x 23 mm |
TP-4.s/H9 | SYG + OPT |
ALARM CO2 OPUŚCIĆ POMIESZCZENIE | 230V~ | 555 x 155 x 23 mm |
TP-4.s2/H2 | SYG + OPT |
OPUŚCIĆ GARAŻ NADMIAR SPALIN | 230V~ | 555 x 155 x 23 mm |
TP-4.ds/H0 | SYG + OPT (×2) | (zgodnie z zamówieniem) /dwustronna/ | 230V~ | 555 x 155 x 23 mm |
TP-4.ds/H4 | SYG + OPT (×2) | WYCIEK AUTOGAZU ZACHOWAĆ OSTROŻNOŚĆ /dwustronna/ | 230V~ | 555 x 155 x 23 mm |
TP-4.ds/H5 | SYG + OPT (×2) | UWAGA! NADMIAR SPALIN /dwustronna/ | 230V~ | 555 x 155 x 23 mm |
TP-4.ds2/H2 | SYG + OPT (×2) | OPUŚCIĆ GARAŻ NADMIAR SPALIN /dwustronna/ | 230V~ | 555 x 155 x 23 mm |
TP-4.As/H0 | SYG + OPT | (zgodnie z zamówieniem) | 12V= | 555 x 155 x 23 mm |
TP-4.As/H1 | SYG + OPT | NIE WCHODZIĆ NADMIAR SPALIN | 12V= | 555 x 155 x 23 mm |
TP-4.As/H3 | SYG + OPT | NIE WJEŻDŻAĆ NADMIAR SPALIN | 12V= | 555 x 155 x 23 mm |
TP-4.As/H4 | SYG + OPT | WYCIEK AUTOGAZU ZACHOWAĆ OSTROŻNOŚĆ | 12V= | 555 x 155 x 23 mm |
TP-4.As/H5 | SYG + OPT | UWAGA! NADMIAR SPALIN | 12V= | 555 x 155 x 23 mm |
TP-4.As/H7 | SYG + OPT | WYCIEK WODORU ZACHOWAĆ OSTROŻNOŚĆ | 12V= | 555 x 155 x 23 mm |
TP-4.As/H8 | SYG + OPT | ALARM CO2 NIE WCHODZIĆ | 12V= | 555 x 155 x 23 mm |
TP-4.As/H9 | SYG + OPT | ALARM CO2 OPUŚCIĆ POMIESZCZENIE | 12V= | 555 x 155 x 23 mm |
TP-4.dAs/H0 | SYG + OPT (×2) | (zgodnie z zamówieniem) /dwustronna/ | 12V= | 555 x 155 x 23 mm |
TP-4.dAs/H4 | SYG + OPT (×2) | WYCIEK AUTOGAZU ZACHOWAĆ OSTROŻNOŚĆ /dwustronna/ | 12V= | 555 x 155 x 23 mm |
TP-4.dAs/H5 | SYG + OPT (×2) | UWAGA! NADMIAR SPALIN /dwustronna/ | 12V= | 555 x 155 x 23 mm |
TP-4.As2/H2 | SYG + OPT | OPUŚCIĆ GARAŻ NADMIAR SPALIN | 12/24V= | 555 x 155 x 23 mm |
TP-4.dAs2/H2 | SYG + OPT (×2) | OPUŚCIĆ GARAŻ NADMIAR SPALIN /dwustronna/ | 12/24V= | 555 x 155 x 23 mm |
TP-4.A24s/H0 | SYG + OPT | (zgodnie z zamówieniem) | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H1 | SYG + OPT | NIE WCHODZIĆ NADMIAR SPALIN | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H3 | SYG + OPT | NIE WJEŻDŻAĆ NADMIAR SPALIN | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H4 | SYG + OPT | WYCIEK AUTOGAZU ZACHOWAĆ OSTROŻNOŚĆ | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H5 | SYG + OPT | UWAGA! NADMIAR SPALIN | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H7 | SYG + OPT | WYCIEK WODORU ZACHOWAĆ OSTROŻNOŚĆ | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H8 | SYG + OPT | ALARM CO2 NIE WCHODZIĆ | 24V= | 555 x 155 x 23 mm |
TP-4.A24s/H9 | SYG + OPT | ALARM CO2 OPUŚCIĆ POMIESZCZENIE | 24V= | 555 x 155 x 23 mm |
TP-4.dA24s/H0 | SYG + OPT (×2) | (zgodnie z zamówieniem) /dwustronna/ | 24V= | 555 x 155 x 23 mm |
TP-4.dA24s/H4 | SYG + OPT (×2) | WYCIEK AUTOGAZU ZACHOWAĆ OSTROŻNOŚĆ /dwustronna/ | 24V= | 555 x 155 x 23 mm |
TP-4.dA24s/H5 | SYG + OPT (×2) | UWAGA! NADMIAR SPALIN /dwustronna/ | 24V= | 555 x 155 x 23 mm |
Wewnętrzne tablice ostrzegawcze LED do wizualnej prezentacji stanu alarmowego pojawiającego się na wyjściach alarmowych
Jedno- lub dwustronne, podświetlane tablice ostrzegawcze LED typu TP-4.s są przeznaczone do wizualnej prezentacji stanu alarmowego pojawiającego się na wyjściach sterujących detektorów WG (garaże podziemne) lub modułów sterujących typu MD lub MDD (systemy detekcji gazów toksycznych).
Posiadają stały napis ostrzegawczy lub informacyjny (standardowa treść lub wg życzenia Klienta) pojawiający się dopiero w momencie podświetlenia (pulsujący w stanie aktywnym). Możliwe jest podłączenie z cichym lub głośnym sygnalizatorem dźwiękowym (działającym w stanie aktywnym).
Tablice posiadają budowę zwykłą – nie mogą być stosowane w przestrzeniach określonych jako strefy zagrożenia wybuchem gazów, par lub pyłów. Są przeznaczone do stosowania wewnątrz budynków.